View Cart
SS304 MESH CAVITY & HAT CLOSER
High-performance ventilation & bushfire-compliant vermin screens for ventilated wall cavities.
First Issued: June 2026 | Compliant with NCC 2022
Select Product Model to View Dimensions & Technical Drawings
Dimensioned Profile Drawing
Model: Climasure 19mm x 2m Weatherboard/Cavity Closer
Product Description & Applications
The Climasure Stainless Steel Mesh Cavity and Weatherboard Closer series comprises premium-grade, corrosion-resistant ventilation profiles designed to seal the base (or top) of external ventilated wall cavity structures. Woven from high-strength Grade 304 stainless steel wire and finished with a durable, non-reflective black powder coating for shadow-line aesthetic concealment, this range provides robust, unrestricted cavity drainage and ventilation while permanently blocking pest, rodent, insect, and wild ember intrusion.
Model-Specific Technical Parameters
| Model Name | Nominal Width (W) | Inside Height (H1) | Front Lip (H2) | Standard Length | Net Free Ventilation Area |
|---|---|---|---|---|---|
| Climasure 19mm Cavity Closer | 19 mm | 70 mm | 15 mm | 2000 mm | 84.2 cm²/m |
| Climasure 35mm Cavity Closer | 35 mm | 70 mm | 15 mm | 2000 mm | 155.1 cm²/m |
| Climasure 54mm Cavity Closer | 54 mm | 70 mm | 15 mm | 2000 mm | 239.2 cm²/m |
| Climasure 25mm Hat Closer | 25 mm | 10 mm | 10 mm (Flange) | 2000 mm | 110.8 cm²/m |
| Climasure 50mm Custom Hat* | 50 mm | 10 mm | 10 mm (Flange) | 2000 mm | 221.5 cm²/m |
*Note: The 50mm Custom Hat Closer corresponds to specialized design requests allowing horizontal or vertical ventilation bridging across wider furring channels or structural frame components.
Active Configuration Metrics
Building Code Compliance (For Certifiers)
- AS 3959:2018 (Bushfire): Meets requirements of Clauses 3.6 & 5.6.5/6.6.5 etc. for construction in Bushfire Attack Levels from BAL-12.5 up to and including BAL-FZ (Flame Zone). Composed entirely of non-combustible material (SS304) with a clear aperture of 1.69mm (under the 2.0mm maximum threshold required for ember screening).
- NCC 2022 (Condensation): Fully complies with the Condensation Management provisions (BCA Volume 1 Section F8 / Volume 2 Section H4). Designed specifically to guarantee high-volume unrestricted ventilation pathways for structural cavity drainage without creating airflow bottlenecks.
- NCC Vermin Proofing: Provides full, unbroken mechanical blockouts preventing pest, insect, and rodent access to timber structures while allowing clear passage of structural moisture runoff.
Engineering Tolerances & Installation
- Dimensional Tolerance: ±2 mm for all nominal dimensions.
- Angular Tolerance: ±2.5° for all profiled angles.
- Corrosion Resistance: Grade 304 Stainless Steel (SS304) is inherently resistant to harsh industrial pollutants, marine salts (suitable for C4 and C5 coastal corrosion zones), and UV breakdown. Black powder coat increases active life span.
- Architectural Install: Fix directly to structural timber frame plates or steel studs using mechanical fastners (nails, screws, or heavy-duty staples) at 300mm max centres prior to vertical cavity battening. Align cleanly and butt join.
Architectural Specification Writer (Copy to Specification Files)
Select a model above and copy this standard NatSpec specification block for project drawings and master documents:
© 2026 Climasure Pty Ltd. All technical parameters are correct at time of publishing.